Valve Cleaning And Maintenance Methods
Cleaning steps
The components of the valve must undergo the following process treatment before assembly:
1. According to the processing requirements, some components need to be polished, and the surface must not have any processing burrs, etc.
2. All components undergo degreasing treatment.
3. After degreasing is completed, acid washing and passivation are carried out. The cleaning agent does not contain phosphorus.
4. After pickling and purification, rinse thoroughly with pure water to ensure no chemical residue remains. This step is omitted for carbon steel components.
5. Dry each component one by one with non-woven fabric, ensuring no lint or other impurities remain on the surface of the component, or blow dry them with clean nitrogen.
6. Use non-woven fabric or precision filter paper dipped in analytical pure alcohol to wipe each component one by one until there is no dirt or color.
Daily maintenance
1. Attention should be paid to the storage environment of valves. They should be stored in a dry and well-ventilated indoor area, and both ends of the passage should be blocked.
2. Valves should be inspected regularly, and the dirt on them should be removed. Anti-rust oil should be applied to their surfaces.
3. After the installation and application of the valves, regular maintenance should be carried out to ensure their normal operation.
4. Check whether the sealing surface of the valve is worn and carry out maintenance or replacement as the situation requires.
5. Check the wear of the trapezoidal thread of the valve stem and the valve stem nut, whether the packing is outdated or ineffective, etc., and make necessary replacements.
6. The sealing performance of the valve should be tested to ensure its performance.
7. The valves in operation should be in good condition, with all bolts on the flanges and brackets complete, the threads undamaged and no loosening.
8. If the handwheel is lost, it should be replaced in time and cannot be replaced by an adjustable wrench.
9. The packing gland must not be skewed or have no pre-tightening clearance.
10. If the valve is used in a harsh environment and is prone to contamination by rain, snow, dust, sand and other contaminants, a protective cover should be installed on the valve stem.
11. The scale on the valve should be kept complete, accurate and clear. The lead seal and cap of the valve.
12. The insulation jacket should be free from depressions and cracks.